Form #43155040
May 2013
INSTALLATION AND OPERATION INSTRUCTIONS
OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and
understood before installing, operating or servicing this heater.
INFRARED RADIANT TUBE HEATER
Two Stage Pull Through System (Negative Pressure)
Models:
L
T
U
SERIES:
80, 90,
100,
110, 120,
125,
130, 140,
150,
160,
175, 180, 200, 225, 250) – N7/L7
L
T
S
SERIES:
40, 50,
60,
75,
80, 90,
100,
110, 120,
125,
130,
140, 150, 160, 175, 180, 200, 225, 250) – N7/L7
!
INS
TALLER
:
This manual is the property of the owner. Please present this manual to the
owner when you leave the job site.
▲WARNING: Improper installation, adjustment, alteration, service, or maintenance can
cause property damage, injury or death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
IF YOU SMELL GAS: FOR YOUR SAFETY
FOR YOUR SAFETYFOR YOUR SAFETY
FOR YOUR SAFETY
!
!!
!
DO NOT
DO NOTDO NOT
DO NOT try to light any appliance.
!
!!
! DO NOT
DO NOTDO NOT
DO NOT touch any electrical switch; DO NOT
DO NOTDO NOT
DO NOT use any
telephone in your building.
!
!!
! IMMEDIATELY
IMMEDIATELYIMMEDIATELY
IMMEDIATELY call your gas supplier from a neighbor's
telephone. Follow the gas supplier's instructions. If you
cannot reach your gas supplier, call the fire department.
DO NOT
DO NOT DO NOT
DO NOT store or use gasoline or other
store or use gasoline or other store or use gasoline or other
store or use gasoline or other
flammable vapors and liquids in the
flammable vapors and liquids in theflammable vapors and liquids in the
flammable vapors and liquids in the
vicinity of
vicinity of vicinity of
vicinity of
this or any other appliance.
this or any other appliance.this or any other appliance.
this or any other appliance.
!IMPORTANT:
!IMPORTANT:!IMPORTANT:
!IMPORTANT:
SAVE THIS MANUAL FOR FUTURE REFERENCE.
SAVE THIS MANUAL FOR FUTURE REFERENCE.SAVE THIS MANUAL FOR FUTURE REFERENCE.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
SPACE
SPACESPACE
SPACE-
--
-RAY
RAYRAY
RAY
Post Office Box 36485 (28236) • 305 Doggett Street (28203) • Charlotte, North Carolina
Phone (704) 372-6391 • Fax (704) 332-5843 • www.spaceray.com • email: info@spaceray.com
Vista de pagina 0
1 2 3 4 5 6 ... 62 63

Indice de contenidos

Pagina 1 - INFRARED RADIANT TUBE HEATER

Form #43155040 May 2013 INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly

Pagina 2 - SECTION DESCRIPTION PAGE

Form #43155040 May 2013 -9- 12(30cm)18(46cm)5 1/2(14cm)108(275cm)92(234cm)330 1/2(839cm)84(213cm)11(28cm)28(71cm)12(30cm)Bot

Pagina 3 - 3.0) GENERAL INFORMATION

Form #43155040 -10- May 2013 8.2) LTU 80-175 SERIES HEATER ASSEMBLY OVERVIEW Typical Assembly Overview(LTU175-40 Shown)Tube Flange12 Radial Hole fo

Pagina 4 - May 2013 -3

Form #43155040 May 2013 -11- 8.3) LTU 180-250 SERIES HEATER ASSEMBLY OVERVIEW Draft InducerControl BoxAluminized Calorized Steel Tube (

Pagina 5 - -4- May 2013

Form #43155040 -12- May 2013 8.5) LTU 80-130 SERIES HEATER ASSEMBLY Sheet metal parts, particularly reflectors and vent have sharpedges. Alway

Pagina 6 - SUSPENSION HAZARD

Form #43155040 May 2013 -13- 3. Assembly the reflectors onto the body section. Leave 3” space between the tube flange an

Pagina 7 - -6- May 2013

Form #43155040 -14- May 2013 7. Insert SJO cable through the strain relief bushing of the control box and connect to appropriate terminal blocks. R

Pagina 8 - May 2013 -7

Form #43155040 May 2013 -15- 3(control box to reflector)See Detail A & B982 overlap99999989991 overlapSee Detail BSee Deta

Pagina 9 - 8.1) LTU SERIES DIMENSIONS

Form #43155040 -16- May 2013 9.0) LTS SERIES SPECIFICATIONS Model Model Model Model No.No.No.No. InputInputInputInput,,,, Btu/hrBtu/hrBtu/hrB

Pagina 10 - May 2013 -9

Form #43155040 May 2013 -17- LTS SERIES LTS SERIES LTS SERIES LTS SERIES CONTROL/DRAFT INDUCERCONTROL/DRAFT INDUCERCONTROL/DRAFT INDUCE

Pagina 11 - (LTU175-40 Shown)

Form #43155040 -18- May 2013 C.C.C.C. LTS 225LTS 225LTS 225LTS 225----250 Body Package Descriptions250 Body Package Descriptions250 Body Package De

Pagina 12 - May 2013 -11

Form #43155040 May 2013 -1- TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1.0) Safety ...

Pagina 13 - Side View

Form #43155040 May 2013 -19- 11.0) LTS SERIES TYPICAL LAYOUTS Control UnitDraft Inducer Unit10 FT. Body Section30 FT.SYSTEM40 FT.SYSTEM

Pagina 14 - May 2013 -13

Form #43155040 -20- May 2013 11.1) LTS SERIES DIMENSIONS Typical Dimensions Up to 50 Ft. Shown Models:LTS 40, 50Models:LTS 60, 75Models:LTS 80, 90,

Pagina 15 - 3/8 Connector

Form #43155040 May 2013 -21- 11.2) LTS 40-175 SERIES HEATER ASSEMBLY OVERVIEW Typical Assembly Overview(LTS 125-40 Ft. Shown)4"OD

Pagina 16 - May 2013 -15

Form #43155040 -22- May 2013 11.3) LTS 180-250 SERIES HEATER ASSEMBLY OVERVIEW Control BoxAluminized Calorized Steel Tube (ALC)(with one 12 radial

Pagina 17 - -16- May 2013

Form #43155040 May 2013 -23- 4. Join the body sections together and secure with tube couplings as follows: TTTThe followinghe follo

Pagina 18 - May 2013 -17

Form #43155040 -24- May 2013 5. For LTFor LTFor LTFor LTS225S225S225S225----250 Mo250 Mo250 Mo250 Modelsdelsdelsdels, join the first two body secti

Pagina 19 - -18- May 2013

Form #43155040 May 2013 -25- 6. Fasten reflectors to all of the tube support/hanger brackets as marked per (DETAIL–A) with (2) #10 shee

Pagina 20 - May 2013 -19

Form #43155040 -26- May 2013 11.5) LTS SERIES - ADDING OPTIONAL 90º ELBOW 1. The optional 90º elbow must be located a minimum of 10 ft. after the

Pagina 21 - 11.1) LTS SERIES DIMENSIONS

Form #43155040 May 2013 -27- Tube Flange12 Radial Hole for 40-200M BTU units only 6 Hole for 225-250M BTU units onlyMPT GasPipe Connect

Pagina 22 - (LTS 125-40 Ft. Shown)

Form #43155040 -28- May 2013 Heater Body1/4-20 Locknut(QTY-3 per flange)Tube Flange12 Radial HoleNote: The wiring connectiondiagram is located on th

Pagina 23 - CUT HAZARD

Form #43155040 -2- May 2013 1.0) SAFETY This heater is a self-contained infrared radiant tube heater. Safety information required during installa

Pagina 24 - May 2013 -23

Form #43155040 May 2013 -29- The purpose of this type mounting is to allow the heater to be mounted in the plane of the roof (particular

Pagina 25 - 10FT Secondary

Form #43155040 -30- May 2013 12.0) ACCESSORY PACKAGES A.A.A.A. Elbow Accessory Package, Part #43208010Elbow Accessory Package, Part #43208010Elbo

Pagina 26 - 40 FT SYSTEM SHOWN

Form #43155040 May 2013 -31- 4. Replace the motor and blower assembly. Tighten the locknuts. 5. Horizontal and 45º draft inducer

Pagina 27 - -26- May 2013

Form #43155040 -32- May 2013 14.0) GAS CONNECTIONS AND REGULATIONS Tighten flexible gas hose and components securely.Flexible metal gas hoses must

Pagina 28 - May 2013 -27

Form #43155040 May 2013 -33- * Available as AccessoriesKEY DIMENSIONS AND COMPONENTS OF THE GAS CONNECTIONS14 to 17(36 to 43cm)Approved

Pagina 29 - -28- May 2013

Form #43155040 -34- May 2013 15.0) INSTRUCTIONS FOR PRESSURE TEST GAUGE CONNECTION SUPPLY PRESSURESUPPLY PRESSURESUPPLY PRESSURESUPPLY PRESSURE

Pagina 30 - May 2013 -29

Form #43155040 May 2013 -35- 16.0) ELECTRICAL CONNECTIONS Failure to do so may result in death or serious injury.This appliance must be

Pagina 31 - 12.0) ACCESSORY PACKAGES

Form #43155040 -36- May 2013 INTERNAL CONNECTION WIRING DIAGRAINTERNAL CONNECTION WIRING DIAGRAINTERNAL CONNECTION WIRING DIAGRAINTERNAL CONNECTION

Pagina 32 - Upright Position

Form #43155040 May 2013 -37- FIELD CONNECTION FIELD CONNECTION FIELD CONNECTION FIELD CONNECTION AND THERMOSTAT AND THERMOSTAT AND T

Pagina 33 - -32- May 2013

Form #43155040 -38- May 2013 C.C.C.C. MANUAL SWITCHMANUAL SWITCHMANUAL SWITCHMANUAL SWITCH CONNECTIONS CONNECTIONS CONNECTIONS CONNECTIONS –

Pagina 34 - CANADA ONLY:

Form #43155040 May 2013 -3- The heater, when installed in aircraft hangars and public garages, must be installed in accord

Pagina 35 - -34- May 2013

Form #43155040 May 2013 -39- 17.0) VENTING Failure to do so may result in death, serious injury, property damage or illnessfrom Carbon

Pagina 36 - ELECTRIC SHOCK HAZARD

Form #43155040 -40- May 2013 Vent CapFlashing2 (5cm)ClearanceThimbleSeal Jointand AnnularSpace10 ft (305cm)or less2 ft (77cm)minimum2 ft (77cm) min

Pagina 37 - CONNECTION WIRING DIAGRAM

Form #43155040 May 2013 -41- MULTIPLE HEATER VENTING (CONNECTIONS INTO A COMMON VENT OR MANIFOLD)MULTIPLE HEATER VENTING (CONN

Pagina 38 - May 2013 -37

Form #43155040 -42- May 2013 Multiple Heater Horizontal Venting Arrangement 4 diametersingle wall ventPlan ViewVent Cap2 (5cm)ClearanceThimble6 (

Pagina 39 - -38- May 2013

Form #43155040 May 2013 -43- B.B.B.B. INDIRECT VENTING (UNVENTED HEATERS)INDIRECT VENTING (UNVENTED HEATERS)INDIRECT VENTING (

Pagina 40 - 17.0) VENTING

Form #43155040 -44- May 2013 In multiple heater applicamultiple heater applicamultiple heater applicamultiple heater applicationstionstionstions, th

Pagina 41 - -40- May 2013

Form #43155040 May 2013 -45- 19.0) LIGHTING AND SHUTDOWN INSTRUCTIONS Failure to do so may result in death, serious injury or propertyd

Pagina 42 - May 2013 -41

Form #43155040 -46- May 2013 21.0) CONTROL COMPONENT LOCATION 3541 Cabinet Assembly2 Air Inlet Plate3 Sight Glass4 Monitoring Light, Red5 Monitorin

Pagina 43 - Connector

Form #43155040 May 2013 -47- 22.0) CLEANING AND ANNUAL MAINTENANCE Failure to do so may result in death or serious injury.Disconnect el

Pagina 44 - 18.0) AIR FOR COMBUSTION

Form #43155040 -48- May 2013 23.0) TROUBLESHOOTING GUIDE Turn on line voltage.Does the greenmonitoring light comeon in the junction box?YesNoIs the

Pagina 45 - -44- May 2013

Form #43155040 -4- May 2013 4.0) MINIMUM CLEARANCES TO COMBUSTIBLES Failure to do so may result in death, serious injury orproperty damage.Combusti

Pagina 46 - 20.0) SEQUENCE OF OPERATION

Form #43155040 May 2013 -49- 30 seconds afterstartup, does the lowfire amber monitoringlight come on in thecontrol cabinet?YesNowhile t

Pagina 47 - LTS/LTU 80-250 Models

Form #43155040 -50- May 2013 Call for heat ends andthe heater shuts off?YesNoTroubleshooting ends.Thermostat is notworking properly.Replace it ifne

Pagina 48 - May 2013 -47

Form #43155040 May 2013 -51- Does the blower turnfreely?Replace the restrictorplate.Contact factory forassistance.Check vent and fresha

Pagina 49 - 23.0) TROUBLESHOOTING GUIDE

Form #43155040 -52- May 2013 24.0) REPLACING PARTS Failure to do so may result in death or serious injury.Disconnect electrical power and gas suppl

Pagina 50 - May 2013 -49

Form #43155040 May 2013 -53- 24.2) REMOVING MAIN BURNER AND GAS VALVE 4355LTS 40-75 ModelsLTS 40-75 ModelsLTS 40-75 Models436612 1. D

Pagina 51 - -50- May 2013

Form #43155040 -54- May 2013 24.3) AIR SWITCH PRESSURE CHECK 0.37 WC+-Connector TeeDigital orInclined WaterManometerscale 0-2w.c.Temporary 1/4 I

Pagina 52 - May 2013 -51

Form #43155040 May 2013 -55- IGNITION MODULE DIAGNOSTICS IGNITION MODULE DIAGNOSTICS IGNITION MODULE DIAGNOSTICS IGNITION MODULE DIAG

Pagina 53 - 24.0) REPLACING PARTS

Form #43155040 -56- May 2013 26.0) REPLACEMENT PARTS GUIDE DRAFT INDUCER COMPONENTSDRAFT INDUCER COMPONENTSDRAFT INDUCER COMPONENTSDRAFT INDUCER CO

Pagina 54 - May 2013 -53

Form #43155040 May 2013 -57- 132111,11a410191816141517223940Items 39 & 40 not includedin Draft Inducer Assembly29-38cItems not inc

Pagina 55 - JUNCTION BOX

Form #43155040 -58- May 2013 CONTROLCONTROLCONTROLCONTROL COMPONENTSCOMPONENTSCOMPONENTSCOMPONENTS Item No.Item No.Item No.Item No. Part N

Pagina 56 - 25.0) INSTALLATION DATA

Form #43155040 May 2013 -5- 5.0) TYPICAL SUSPENSION METHODS Burner must be secured to the mounting flange with nuts.All materials used

Pagina 57 - -56- May 2013

Form #43155040 May 2013 -59- CONTROL BOXCOMPONENTS5758415556636251,51a,52,52a53457610615947436054445351,5274676869707172734140-75M BTU

Pagina 58 - COMPONENTS

Form #43155040 -60- May 2013 BODYBODYBODYBODY COMPONENTSCOMPONENTSCOMPONENTSCOMPONENTS: LTS 40: LTS 40: LTS 40: LTS 40----250250250250 Item I

Pagina 59 - -58- May 2013

Form #43155040 May 2013 -61- BODYBODYBODYBODY COMPONENTSCOMPONENTSCOMPONENTSCOMPONENTS: LTU 80: LTU 80: LTU 80: LTU 80----25025025025

Pagina 60 - Low Fire

Form #43155040 -62- May 2013 27.0) WARNINGS CARD Copies of this card may be ordered at no charge under part no. 43344990 for installation near the

Pagina 61 - -60- May 2013

Form #43155040 -6- May 2013 6.0) LTU SERIES SPECIFICATIONS Model Model Model Model No.No.No.No. InputInputInputInput,,,, Btu/hrBtu/hrBtu/hrBt

Pagina 62 - BODY COMPONENTS

Form #43155040 May 2013 -7- LTU 80LTU 80LTU 80LTU 80----252525250 0 0 0 CONTROL/DRAFT INDUCERCONTROL/DRAFT INDUCERCONTROL/DRAFT INDUCERC

Pagina 63 - FIRE HAZARD

Form #43155040 -8- May 2013 8.0) LTU SERIES TYPICAL LAYOUTS 30 FT.SYSTEM40 FT.SYSTEM50 FT.SYSTEMControl UnitDraft Inducer Unit15 FT. Body Section10